Very truly yours, Ballasts can be expensive to replace and therefore you want to ensure they have a long serviceable life so that you are not prematurely having to do repair work on your paint booth lights. LED bulbs can provide significant cost savings related to the operations of your paint booth however they are more expensive initially. OSHA 29CFR19 10 Section 94 Ventilation and Section 107 Spray Application of Flammable or Combustible Materials. You can determine whether or not an LED light bulb may be better for your paint booth by running a simple calculator like this one here. So, for a true match and a consistent colour, you need the best lighting possible. Paint booth lighting can either be inside accessed or have to be accessed from outside on top or next to the paint booth. In addition a final option to consider is how it is serviced. In particular you want to check to see how many hours of use the ballasts are rated for. A class I division 2 light is sealed and gasketed which prevents any flammable substances from being able to migrate and come in contact with an ignition source. Below is an easy-to-use paint booth regulations checklist designed to help overcome some of these initial frustrations and further ensure proper compliance. Not having sufficient lighting can create issues in being able to achieve quality finishes their free of defects because without proper lighting an operator cannot tell when issues are occurring. Note that our enforcement guidance may be affected by changes to OSHA rules. Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device, Fluid Handling Accessories (Regulators, Agitators, Surge Suppressors), Sandblast Rooms & Sandblast Media Recovery Equipment, review this article on can a room become a paint booth, running a simple calculator like this one here, choosing a selection results in a full page refresh, press the space key then arrow keys to make a selection. The most important thing to consider when evaluating paint booth lighting whether it be to add additional lights in an existing booth or to evaluate lights that maybe be being offered with a new paint booth is that they will meet proper paint booth safety requirements. Our primary carriers include UPS and USPS and for large items a variety of freight carriers. To ensure when your painting your product appears like it would in natural light you want to make sure your paint booth lighting has color corrected bulbs. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. OSHA requirements are set by statute, standards and regulations. Except as otherwise described below, if you are not satisfied for any reason products may be returned within 30 days of shipment for a full credit or exchange (if the product is undamaged). So if you’re considering a new paint booth ensure that the number of lights being proposed is relatively comparable between different booths you may be considering. Foot Candles. Electrical equipment should be properly rated for use in flammable environments. Plus, unlike standard paint booth lights, LED light can be focused directly on one area; Standard light spreads which loses brightness and affects the true color of your finishes. So many, that it can often feel overwhelming and even at times unfair for operators that lack the means to contract proper guidance. Two common options for paint booth lighting bulbs include LED or color corrected T8 lights. 1. This is in response to your letter requesting clarification of standards approving lighting fixtures in spray booths. In the case of spray booth lighting the OSHA standard, 1910.107(b)(10) and (c)(7), states that illumination shall have fixed lighting units outside of the spray booth permitting light to enter through transparent panels. Basic Fire & Electrical Requirements: Signs prohibiting smoking, flames, and sparks should be displayed within 20 ft of the booth. Just enter your email and will send the coupon code to your email. With pre-manufactured paint booths light will be classified as a class I division 2 light. In addition, compliance with the National Electrical Code NFPA 70-1971 is also mandatory. When it comes to lighting, regulatory agencies require that booth light fixtures be approved for Class I, Division II, Groups A-D. The following are eight things to consider when selecting lighting for your paint booth. LeRoy, New York 14482 It merely sets standards which must be met by industries having exposures involving the safety and health of employees. The options you select can help improve visibility and improve the amount of light you receive from the paint booth light as well as ensure that what you see inside the paint booth visually will match what you see in natural sunlight. If you need additional help with paint booth lights you can contact us as we offer a variety of options for your paint booth lighting needs.